The service manual was very usable and clear enough to see the individual values of all of the components (unlike some of the service manuals I have gotten in the past from web sites similar to this one). The price was right and the information was greatly appreciated. It helped me with an otherwise very difficult repair. It was much needed and appreciated. A faster turn around on my order would be nice, but I understand the constraints on your staff's time. Thank you for your service.
Great service!!! Polecam gorąco wszystkim zainteresowanym
Text excerpt from page 198 (click to view)
Page: 142
Service Guide OJ2010
Chapter 4 Failure and Repair Analysis
4.8.05 End of Forms Sensor Test
This test checks the operation of the end of forms sensor on the sensor board. 1. Power OFF the unit. 2. Move the two pin jumper on connector J13 of the system board to the position shown below.
3. Power ON the unit. 4. Check the sensor by performing either of the steps listed below. -- Activate the end of forms flag. -- Place a piece of paper in the manual feed slot.
5. The power light should go on and off as the flag moves past the sensor. If it does not, replace the system board. 6. Power OFF the unit to end the test. 7. Return the jumper to its original pin position after completing the test.